{"id":1049,"date":"2014-05-28T10:00:28","date_gmt":"2014-05-28T18:00:28","guid":{"rendered":"http:\/\/jazzistentialism.com\/blog\/?p=1049"},"modified":"2015-02-11T23:36:41","modified_gmt":"2015-02-12T07:36:41","slug":"spectra-l200-neon-calibration-test","status":"publish","type":"post","link":"http:\/\/jazzistentialism.com\/blog\/?p=1049","title":{"rendered":"Spectra L200 Neon Calibration Test"},"content":{"rendered":"<p>Initial calibration and testing of a\u00a0<a href=\"http:\/\/jazzistentialism.com\/blog\/?attachment_id=1195\">Spectra L200 spectroscope<\/a> using the integrated neon calibration lamp. The analysis was undertaken using &#8220;BASS&#8221;. Click &#8220;Continue reading&#8221; below to see the entire analysis.<\/p>\n<p><img loading=\"lazy\" class=\"alignleft wp-image-1066 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonColour.png\" alt=\"NeonColour\" width=\"857\" height=\"114\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonColour.png 857w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonColour-300x39.png 300w\" sizes=\"(max-width: 857px) 100vw, 857px\" \/><\/p>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<p><!--more--><\/p>\n<h2>Equipment<\/h2>\n<p>Telescope: DSI RC14C (0.35m, f\/7 Ritchey\u2013Chr\u00e9tien)<br \/>\nImaging Camera: Atik314L+ (1392&#215;1040, 0.65\u00b5m)<br \/>\nSpectroscope: Spectra-L200 with 600 l\/mm diffraction grating<\/p>\n<h2>Images<\/h2>\n<p>Images of the Spectra L200 integrated neon lap were taken at a variety of exposures from 1 to 5 seconds. Figure 1 shows the neon calibration lamp centred at approximately 6150 Angstroms. The exposure is 5 seconds at Bin2, with the slit adjusted to approximately 25 microns on the slit adjustment dial.<\/p>\n<div id=\"attachment_1051\" style=\"width: 721px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RAWNeon.png\"><img aria-describedby=\"caption-attachment-1051\" loading=\"lazy\" class=\"wp-image-1051 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RAWNeon.png\" alt=\"RAWNeon\" width=\"711\" height=\"531\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RAWNeon.png 711w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RAWNeon-300x224.png 300w\" sizes=\"(max-width: 711px) 100vw, 711px\" \/><\/a><p id=\"caption-attachment-1051\" class=\"wp-caption-text\">Figure 1: The appearance of the RAW fits file from the Atik314L+ imaging camera.<\/p><\/div>\n<p>Camera angle has been [incorrectly] adjusted to present\u00a0&#8216;vertical&#8217; lines. The residual tilt is evident.<\/p>\n<h2>Analysis<\/h2>\n<h3>1.\u00a0\u00a0\u00a0 Raw profile<\/h3>\n<p>An active binning area covering the central portion of the image was selected:<\/p>\n<p><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RawNeonCrop.png\"><img loading=\"lazy\" class=\"alignleft size-full wp-image-1058\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RawNeonCrop.png\" alt=\"RawNeonCrop\" width=\"716\" height=\"223\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RawNeonCrop.png 716w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/RawNeonCrop-300x93.png 300w\" sizes=\"(max-width: 716px) 100vw, 716px\" \/><\/a><\/p>\n<p>Figure 2 shows the resulting uncalibrated spectral profile as it appears in BASS (click to enlarge image).<\/p>\n<div id=\"attachment_1056\" style=\"width: 951px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonUncalibrated.png\"><img aria-describedby=\"caption-attachment-1056\" loading=\"lazy\" class=\"wp-image-1056 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonUncalibrated.png\" alt=\"NeonUncalibrated\" width=\"941\" height=\"428\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonUncalibrated.png 941w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonUncalibrated-300x136.png 300w\" sizes=\"(max-width: 941px) 100vw, 941px\" \/><\/a><p id=\"caption-attachment-1056\" class=\"wp-caption-text\">Figure 2: Uncalibrated neon spectral profile.<\/p><\/div>\n<h3>2.\u00a0\u00a0\u00a0 Calibrated profile<\/h3>\n<p>Figure 3 shows the result of a simple two point (linear) calibration and provides the following values:<\/p>\n<ul>\n<li>Dispersion = 1.08 \u00c5\/pixel.<\/li>\n<li>Average FWHM = 2.18<\/li>\n<li>R = 2818 @ 6143.06\u00c5<\/li>\n<\/ul>\n<div id=\"attachment_1057\" style=\"width: 951px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon2PointCalibration.png\"><img aria-describedby=\"caption-attachment-1057\" loading=\"lazy\" class=\"wp-image-1057 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon2PointCalibration.png\" alt=\"Neon2PointCalibration\" width=\"941\" height=\"428\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon2PointCalibration.png 941w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon2PointCalibration-300x136.png 300w\" sizes=\"(max-width: 941px) 100vw, 941px\" \/><\/a><p id=\"caption-attachment-1057\" class=\"wp-caption-text\">Figure 3: Two point linear calibration.<\/p><\/div>\n<p>Direct measurement of a number of other lines shows results that are within 0.2 \u00c5 of published values.<\/p>\n<p>Figure 4 shows the result of calibration using 6 points and a quadratic fit. The resulting RMS is 0.0878.<\/p>\n<div id=\"attachment_1063\" style=\"width: 951px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon6PointCalibration.png\"><img aria-describedby=\"caption-attachment-1063\" loading=\"lazy\" class=\"wp-image-1063 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon6PointCalibration.png\" alt=\"Neon6PointCalibration\" width=\"941\" height=\"428\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon6PointCalibration.png 941w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/Neon6PointCalibration-300x136.png 300w\" sizes=\"(max-width: 941px) 100vw, 941px\" \/><\/a><p id=\"caption-attachment-1063\" class=\"wp-caption-text\">Figure 4: Multi-point calibration.<\/p><\/div>\n<p>Measurement of additional lines shows improved results over that of the two point calibration, yielding values that are within 0.025 \u00c5 of published values.<\/p>\n<h2>BASS Measurement Tool<\/h2>\n<p>The BASS measurement tool allows easy selecting and measuring of features in a profile. The typical output appears as follows:<\/p>\n<p>Profile\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 : CCD Image 41.fit<br \/>\nSelected Start \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 6258.2\u00c5 (430.07 px)<br \/>\nSelected End \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 6273.9\u00c5 (444.56 px)<br \/>\nSelected Width \u00a0 \u00a0 \u00a0 \u00a0 : 15.7\u00c5 (14.49 px)<br \/>\nMax Flux \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 26582.7 at 6266.6\u00c5 (437.82 px)<br \/>\nMin Flux \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 400.79 at 6258.21\u00c5 (430.07 px)<br \/>\nFlux Range \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 26181.91<br \/>\nAverage Flux \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0: 3797.6 (RMS 8084.89)<br \/>\nStd Deviation \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 : 7137.49<br \/>\nSNR \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0: 0.53<br \/>\nContinuum Slope\u00a0\u00a0\u00a0\u00a0 : 25.1 ADU\/\u00c5\u00a0 0.27 ADU\/px<br \/>\nFWHM \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0: 2.11 \u00c5 (R = 2971 @6266.6\u00c5)<\/p>\n<h2>Formatted Profile<\/h2>\n<p>Figure 5 shows a formatted profile produced in BASS. A synthesised colour image strip featuring the neon emission lines appears below the profile.<\/p>\n<div id=\"attachment_1070\" style=\"width: 1897px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonwithColour.png\"><img aria-describedby=\"caption-attachment-1070\" loading=\"lazy\" class=\"wp-image-1070 size-full\" src=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonwithColour.png\" alt=\"NeonwithColour\" width=\"1887\" height=\"1087\" srcset=\"http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonwithColour.png 1887w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonwithColour-300x172.png 300w, http:\/\/jazzistentialism.com\/blog\/wp-content\/uploads\/2014\/06\/NeonwithColour-1024x589.png 1024w\" sizes=\"(max-width: 1887px) 100vw, 1887px\" \/><\/a><p id=\"caption-attachment-1070\" class=\"wp-caption-text\">Figure 5: Formatted neon spectral profile in BASS.<\/p><\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Initial calibration and testing of a\u00a0Spectra L200 spectroscope using the integrated neon calibration lamp. The analysis was undertaken using &#8220;BASS&#8221;. Click &#8220;Continue reading&#8221; below to see the entire analysis.<\/p>\n","protected":false},"author":4,"featured_media":1066,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[19],"tags":[],"_links":{"self":[{"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1049"}],"collection":[{"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1049"}],"version-history":[{"count":27,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1049\/revisions"}],"predecessor-version":[{"id":1551,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1049\/revisions\/1551"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=\/wp\/v2\/media\/1066"}],"wp:attachment":[{"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1049"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1049"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/jazzistentialism.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}